                           Item | 
                                  LINE INTERACTIVE UPS | 
                        
                        
                          | Capacity | 
                           | 
                        
                        
                          | Application | 
                          
                              - Line interactive 
                              UPS with AVR for computers 
                                and general purposes
 
                            | 
                        
                        
                          | Input voltage Range | 
                          
                              - 160 to 280 V, Single 
                              Phase AC
 
                            | 
                        
                        
                          | Input 
                          Frequency | 
                           | 
                        
                        
                          | Wave 
                          Form | 
                          
                              - Stepped Approximation to 
                              Sinewave
 
                            | 
                        
                        
                          | Output 
                          Voltage | 
                          
                              - 
                                
AVR output voltage in AC mode : 
                                  230 V ± 9%, 50 ± 3 Hz. 
                               
                            - 
                                
UPS 
                                output voltage in battery mode : 230 V ± 10%, 50 
                                ± 0.5 Hz at load power factor of not less than 
                                0.6 log . 
                             
                            | 
                        
                        
                          | Switching Device | 
                           | 
                        
                        
                          | Switching Frequency | 
                           | 
                        
                        
                          | Switching over time (From AC 
                            mains to UPS mode on power failure) | 
                          
                              - 10 Milliseconds (Maximum)
 
                            | 
                        
                        
                          | Efficiency (at rated output 
                            voltage and frequency) | 
                          
                              - Inverter Efficiency : Minimum 70%
 
                            | 
                        
                        
                          | Regulation  | 
                          
                              - Total Variation of voltage from no load 
                                will not exceed 10%
 
                            | 
                        
                        
                          | Total 
                          Harmonics distortion | 
                           | 
                        
                        
                          | Overload | 
                          
                              - Withstands 10% overload for at least 10 
                                mins. in mains mode
 
                            | 
                        
                        
                          | Protections | 
                          
                              - If input voltage goes outside the range 
                                160 to 280 V, the system will switch over to battery mode. 
 
                            - Over voltage, Short 
                            Circuit & Overload of 
                              UPS output terminals. 
 
                            - Protection against over discharge (the 
                              load will be cut-off as soon as voltage of battery terminals falls bellow 
                              10.5 V for 12 V and 21 V for 24 V battery Systems.)
 
                            | 
                        
                        
                          | Indicators & Meters | 
                          
                              - Mains mode
 
                            - UPS mode 
 
                            - Battery low
 
                            | 
                        
                        
                          | General | 
                          
                              - Ambient temperature : 0 to 550 C 
                                . 
 
                            - Relative humanity : up to 95% 
                              non-condensing
 
                            | 
                        
                        
                          | Battery bank  | 
                          
                            - 12 Volts Sealed Lead Acid Valve Regulated Type (VRLA) 
 
                            | 
                        
                        
                          | Battery make | 
                          
                            - Sunshine / AMCO/ WAKAI or other make
 
                            | 
                        
                        
                          | Battery type | 
                          
                              - Sealed lead Acid Valve 
                              Regulated Type (VRLA)
 
                            |